You were everything about Brilliant service.

The best way to see how a Reach & Wash System can help your business, is to see it for yourself. Follow our method using the constructor Pro brush or the easy brush youre going to be twice as fast as you were doing it traditional. The terms demineralization and deionization are used somewhat interchangeably by the industry. The reason that people are being sold reverse osmosis membranes isthat theyre being told that if the TDS of the tap water is X depending on the person telling the story then you need an RO to filter the water and thats not true. As for the winter, using hot water has definitely enabled me to keep working. Youve already taken the dirt off the windows. Ionic Systems Australian and Gordon have been instrumental in supporting our business, Adelaide Solar Care and Australian Solar Care in expanding our operations around Australia building confidence in supplying great equipment and superior Ionic Aqua Audit, Australian TDS Water Readings. Need resin, check out our best valueUnger 25L Resin Bag, This product offers additional discounts when buying in bulk. Now when we say that its the alternative its not true, de-ionization is the only way to make de-mineralized water or to make spot free (pure water) under all conditions. So RO is not the best filter, DI is a simple plug and play solution but the downside of DI is simply that its a consumable that costs. Realm Property Services can't thank Gordon at Ionic systems enough - His product knowledge and customer service is second to none. Highly recommended. Unfortunately there isn't a straight answer, there are too many variables, some of these are in your control, and some are not. So DI is the true spot free water filter and thats why youll see that all reverse osmosis systems are RO/DI for our industry. So the myth that we want to bust is that you never need an RO from a water perspective. Deionization completely filters these impurities and allows the glass and window frame to dry completely spot free. Other businesses that may also use deionized water include: Total Dissolved Solids (TDS) are the total amount of mobile charged ions, including minerals, salts or metals dissolved in a given volume of water, expressed in units of mg per unit volume of water (mb/L), also referred to as parts per million (ppm). To estimate the running cost of DI only is to divide the TDS by a hundred, so if youve got TDS of 500 then 500 divided by 100 is five pounds an hour. Thats all from us at Wash-IT, a proud representative of www.FutureofCleaning.com the manufacturers of the Reach-IT range of water fed poles sold buy us here in the UK. So a hundred percent of the water that goes through a DI filter is actually pure and spot free so theres no waste. Why you need an RO system is to save money on DI because youre always using DI. Use tab to navigate through the menu items. Just buy a DI at the beginning of your business. We are confident we can go to that next level with Ionic system. The system maintains the immaculate appearance of our fleet in minimal time and effort without the use if harmful detergents. Now if you use this method you can use any DI tank you want. Can highly recommend this quality product. Then with that efficiency that your getting from those two products you can then do the maths and work out when is the right time to buy an RO membrane. You could work in 2 inchesof snow if you wanted to. Because they use pressure to separate the water molecules that are pure then you usually can only go to three stories or two stories depending on the local tap pressure and if you struggle then you might need a booster pump or you may need to use a buffer tank and a delivery pump. The passage of water through the first exchange material removes the calcium and magnesium ions just as in the normal softening process. VAT Reg. The hydrogen ions then combine to form water (H+ plus OH- equals HOH or H2O). For more information about our sister companies please visit: Copyright 2022 Ionic Systems Australia. For the uninitiated, deionizing resin is a consumable component, found in Window Cleaning systems to purify water. In the UK, Tap water TDS readings range from 30ppm to 500ppm (parts per million), and knowing where you fall on this scale will give you an idea of the lifespan you can expect from your resin. Use whatever method you can to use DI whether its the drive-thru car wash method or you just pay the hourly rate for using the DI water and buy yourself a, Thats all from us at Wash-IT, a proud representative of. Is this the year of waterfed and pure water cleaning? When you need an RO is a business decision, the RO is a pre-filter to your DI and the function of the RO is to save your DI consumption. ( 0.9ppm TDS as CaCO3). Now that is inspiring if you think about it because what theyre doing is exactly the same as what were doing when were window cleaning. It can be used as part of a 4 stage RO/DI filtration system, or as a stand alone means to purify water (for more on these, check out our articletypes of filtration, RO/DI or DI Only). As you might expect, the 11 Litre will need replacing more often, but a 25L bag of resin will provide two full refills of this size vessel. ANION BED DEIONIZERS have a high capacity to remove negatively charged dissolved ionic contaminants such as carbonate, bicarbonates, sulfates, chlorides, nitrates and silica (used in conjunction with a cation deionizer they can produce a quality in excess of 400,000 ohm/cm.

The process used for removal of all dissolved salts from water is referred to asdeionization. So heres the thing, if you could reduce the use of DI resin another way then you could save money without needing to buy an RO and thats what we want to share with you. In a soft water area you can be looking at a few months between resin changes, by comparison, hard water can go through resin in a few days (and this is where a more complex filtration systems can lower running costs - See RO/DI LINK). Buy yourself an amazing brush that will clean windows four times faster than a traditional window cleaner and two times faster than and a cheaper brush. Youll put the brush on the glass, go up and down on every piece of glass in less than 10 seconds per pane and what youre doing is simply rinsing off the spots or the dirty water that is just the local tap water. Whats happening out there which is the criminal part is that people are being sold pure water systems that are RO, being told that they need the RO when they startup and then because the RO systems are so expensive they get sold a cheaper pole and a cheaper brush and thats the bit thats wrong. From the set up presentation to the hands on training of our staff.

So the actual decision of a reverse osmosis membrane system is not the TDS of the tap water, it is how much the DI is costing you. So if the local tap water is TDS 100 that youve used, then its the water spots from the 100 TDS water that youre washing off. If its TDS 500, its the spots from the TDS 500 water that youre washing off and not the dirt. They tell you that you need an RO and then they charge you for your carbon filter and your DI resin and everything else at a proprietary rate. So if youve got TDS 500 but youre only going to use it two hours a week somebody will say to you you need RO because the TDS is 500 but the reality is that if you didnt have RO it would cost you five pounds an hour using DI only. Get used to your tools and enjoy the process and then when you bring in an RO of course once youre going and use it and of course itll save you money because youre actually using your pole, brush and system efficiently. These are what cause spotting on windows after they dry and necessitate the use of squeegees. A reverse osmosis membrane uses pressure to purify the water and in doing that it means that it usually cant be used above three stories (you would need a booster pump or you need a buffer tank and a delivery pump). I'd highly recommend Ionic Systems Australia and their products to anybody in the industry. In order to budget it's important to regularly check the lifespan of your resin and keep a record. So the industry has a myth now that depending on who youre listening to and what they want to sell to you is that you need an RO system if your tap water is at TDS 200, TDS 150 and TDS 100 and weve caught some people being sold RO filters with a TDS as low as 50 which is really bordering on immoral. There are also long life vessels such as the HydroPower, that distribute the water more evenly through the resin, improving the amount of pure water you can create from the same volume of resin. If you have a tap water of TDS 500 which is really high and youre only going to use your your pure water system at the beginning and only using it two hours a week, youve just got a couple of jobs that you dont want to use your traditional method way. Maintenance, both preventative, and proactive, looking after some of Australian most rich in history Heritage buildings.

Company No. Where can I buy a pure water window cleaning setup in Canada?

An RO (Reverse Osmosis) uses separation, so water molecules that gather around minerals cluster and then when under pressure theyre pushed against the membrane of the reverse osmosis system. We hope you're enjoying the new shopping experience at Window Cleaning Warehouse. How to Price (quote) Window Cleaning Jobs In Canada. So five pounds an hour two hours a week is 10 a week, 40 weeks a year times 10 a week equals 400 a year running cost. A system using 650 Litres per day is going to need changing far more often than a single operator using only 300 litres. Worse, if the glass is not properly maintained through regular cleaning, these minerals will eventually permanently stain the glass. If youre using constructor Pro brush then once you get the hang of it (because it takes a little bit of time to get used to) then youre going to be working four times faster.

There is another way to save DI resin and its inspired by the drive-thru car wash. In simple terms, by controlling the electric charge of ions in the water, it is possible to remove the TDS. CATION DEIONIZERS have a high capacity to remove positively charged dissolved ionic contaminants such as calcium, sodium, magnesium, potassium, iron, and manganese (used in conjunction with an anion deionizer they can produce a quality in excess of 400,000 ohm/cm. Just get in touch to arrange a free, no-obligation demonstration. DI Resin Window Cleaning Kit- Various Pole Sizes 9ft Mini, 17ft, 24ft, 32ft Hydra Water Fed Pole, DI Resin Window Cleaning Kit- Various Pole Sizes, Choose from a 9ft, 17ft, 24ft, and 32ft Hydra Glass Carbon Composite Pole Size with 270mm Vikan Brush, 25lts DI MB Resin, enough to fill the Bottle Twice, Pole Size of Choice in Hydra Glass Carbon Range. Now DI (De-Inonization) is the alternative. GB851047444.

DI resins attract non-water ions and replace them with water ions, leaving a more pure water form. Then at the end of that you go back around and you just quickly quickly rinse every single piece of glass. A little info on DI mixed bed resin and its function. If its TDS 500, its the spots from the TDS 500 water that youre washing off and not the dirt. Tap water is classified as hard or soft, however in reality it's not quite so black and white. The most common question that we ask operators, and we near always get the same answers . A de-ionization system is basically a tank full of beads that are 50% lets say supercharged positively 50% supercharged negatively and they they attract the minerals away from the water and the minerals stick to the beads. It's a fantastic system, it cleans better, the work is easier. However even this isn't going to give an exact length, as tap water TDS readings are known to change from time to time, you will often find changes even between seasons. This is because some of the RO systems have proprietary components that eat into your savings and take a good part of those savings back from you.

Two of our most common sizes are 11L & 25L, however there are plenty of other sizes available. If you get a brush like a constructor Pro brush (which takes some learning to use) but if youve never learned anything else and it will take a lot less learning, then you can be working four times faster than a traditional window cleaner. 05018345. While the term demineralization is generally better understood, deionization is especially apt. Since most dissolved solids in tap water are salts (the things that cause spotting on windows), this process is very efficient and creates a high level of water purity similar to that of distilled water. Our own "Ionic Customers" using our professional equipment are available Australia wide. We hope that this blog is actually the most powerful blog of all and its based on whether you need an RO or a DI filter when youre a water fed window cleaner, especially when youre just starting out. How long your resin will last before it stops purifying the water sufficiently will be dependent on a number of variables, but there are a few major things that effect its life, more so than others. You can use a DI tank anywhere from 129 upwards but youve saved yourself all the hassle of reverse osmosis membranes because theyre not good filters for window cleaners. They fail to go through if they are clustered around a mineral and they go through if they are not anywhere near a mineral, so basically 50% of water goes through to your window cleaning pole as pure spot free water and 50% of the water goes through to waste. Its not a water decision its a business decision. Whether they are ground minerals picked up along the way, or additives that make it safe for drinking, none of these impurities do your windows any good. Theres nothing wrong with that but were trying to save you money when youre a startup. When you can prove that youre going to get a return on investment inside of one year then its the right time to buy an RO. Resulting in spot-free results. For the sake of simplicity, we usually advise that water under 150ppm is considered soft, anything above is hard water. Water is passed through a special substance called an "ion exchange resin." These new ions then combine to form water. 2021 Window Cleaning Warehouse Ltd. is a Company Registered in England and Wales. Like the cationic, the anionic resin is also made from styrene, but contains positively charged quaternary ammonium groups, and will be pre-charged with hydroxide ions. The cationic resin is typically made from styrene containing negatively charged sulfonic acid groups, and will be pre-charged with hydrogen ions. Deionization (DI) is a water filtration process whereby total dissolved solids (TDS) are removed from water through ion exchange. When you go to or through a drive-thru carwash the water that you use in a drive-through car wash is tap water and then they offer you a spot free rinse. Deionization. Professional Car Washing/Detailing Companies. So first if your TDS is 100 then its going to cost you around a pound an hour using DI only and it would cost you lets say 10p an hour RO only depending on whos supplying you with your RO system. There is no efficiency in the pure water function, you could buy 100 DI tank or you could buy 10,000 amazing cart system with pumps and heaters and all sorts of things and you will not get a significant improvement in the efficiency of you as a window cleaner. Ryan Cochrane of Peak Property reviews The Window Cleaning Store. Thanks Gordon. Comments have to be approved before showing up. You can use our RO/DI system for your business and decided whether to make it static in your shop/home or whether to make it on-demand in your vehicle. Water from the tap contains many impurities. We are then able to clean high or dangerous windows safely from the ground through the use of poles, which deliver pure water for a perfect clean every time. This resin will attract the positively charged ions in the water (Ca++, Mg++, SO4--, etc.) Unlike home equipment, deionization units also remove all other positive metallic ions in the process and replace them with hydrogen ions instead of sodium ions. However if you get a rigid 100% carbon fibre or high modulus carbon fibre water fed pole, youre going to have more precision and more accuracy thats going to reflect in your hourly rate and efficiency. ( 0.9 ppm TDS as CaCO3). So youll agitate, then rinse. and releases an equivalent amount of hydroxide (OH-). The only way to get a fixed idea on the life of your resin is through trial and error using the equipment, as you begin to track how many litres of pure water you use every day, and the size of the filtration system you are using. Now you cant get a return on investment on an RO thats costing you 2,000 or 1,600 if its only 400 a years worth of resin that you would have used anyway. How does DI (deionization) of water result in spot-free window cleaning? Powered by Shopify. This resin will attract the negatively charged ions (HCO3-, Cl-, SO4--, etc.) If you have any feedback with the new layout, please feel free to get in touch. So it makes more sense as a businessperson to defer the purchase of an RO system unless you already know that youre going to be using it all the time and youve done the maths to further the investment. Before then you should use DI and get your efficiency up get your business rolling. Mixed bed DI resin is made up of Cation beads and Anion beads.